GIWU Series Ultrasonic Flow Meter

Ultrasonic flow meters are the equipment of choice whenever the contact with the measured fluid isn't possible. Ultrasonic measurements are made by attaching two transducers onto the outside of a pipe. GIHU and GIWU series transit time ultrasonic flow meters measure the time difference between the ultrasonic pulse going upstream and the one propagating downstream. These sound waves are generated by a pair of transducers. The difference between the two intervals of time is a function of flow direction and velocity, and it represents an accurate measure for the average velocity of the liquid flowing through a pipe.

Description

Ultrasonic flow meters are the equipment of choice whenever the contact with the measured fluid isn't possible. Ultrasonic measurements are made by attaching two transducers onto the outside of a pipe. GIHU and GIWU series transit time ultrasonic flow meters measure the time difference between the ultrasonic pulse going upstream and the one propagating downstream. These sound waves are generated by a pair of transducers. The difference between the two intervals of time is a function of flow direction and velocity, and it represents an accurate measure for the average velocity of the liquid flowing through a pipe.

Specification

  • Flow range, ±0.03 ft/s ~ ±40 ft/s (±0.01 m/s~ ±12 m/s)
  • Measurement range: 1"~48"(25mm~1200mm)
  • Output, OCT Pulse output:0~5000Hz,
  • Analog output:4~20mA,max load 750Ω
  • Power type: 10~36VDC/1A for wall mounted type
  • Battery rechargeable for handheld type(11.1V rechargeable Lithum Battery Power,continuous operation of main battery 16 hours)
  • SD card is option for handhled type, storage 1GB,Max 512 files,Interval:5 60 seconds

Feature

  • Low pressure loss, easier installation & operation, maintance
  • Clear, user-friendly menu selections make flowmeter simple and convenient to use, daily, monthly,yearly flow totalized calculation
  • Less hardware components, low voltage broadband pulse transmission, low consumption power
  • Parallel operation of positive, negative and net flow totalizes with scale factor (span) and 7 digit display, while the output of totalize pulse and frequency output are transmitted via relay and open collector

Application

  • lt is a non-contact method for flow measurement, so it provides an effective solution to strong corrosion, radioactivity, blockage, viscosity, low pressure loss, non-leakage media, air bubbles, and particles
  • Factory sewage discharge monitoring, production process water consumption measurement, milk flow measurement, ore dressing slurry flow measurement
  • Sodium aluminate and other process flow measurement and control, genset coil cooling water flow measurement, cooling circulating water flow measurement, oil well water injection flow measurement

Technical Data

Flow Range ±0.03ft/s - ±20ft/s (±0.01 m/s - ±6 m/s)
Accuracy ±1% of measured value
Pipe Size Clamp - on: (25mm - 1200mm)
Pipe Material Carbon steel, stainless steel, PVC
Output OCT Pulse output: 0 - 5000Hz.
Analog output: 4 - 20mA, max load 750Ω
Communication Interface RS485; Modbus
Power Supply 10 - 36V DC/1A
Keypad 16(4x4) key with tactile action
Display 20x2 lattice alphanumeric, back lit LCD
Temperature Transmitter: 14°F...122°F (+10°C...+50°C)
Transducer: 32°F...176°F (-10°C...+80°C)
Humidity Up to 99% RH, non - condensing
Protection Transmitter: PC/ABS, IP65
Transducer: Encapsulated design, IP68
Transducer Cable Standard cable length: 30ft(9m)
Weight Transmitter: approximately 0.7kg
Transducer: approximately 0.4kg
(One set weight is 7kg after package)